Vista de pagina 0
INGLENOOK
MODEL IWZC-02
ZERO CLEARANCE NON-CAT FIREPLACES
OWNERS MANUAL
© 2006
Version: 7.0
1
This manual was written to ensure safe, efficient, and dependable operation of your Country Flame Inglenook high-
efficiency fireplace system. Please read and understand these instructions and ensure conformance to all local codes
before installation or operation of this product.
CAUTION: Do not attempt to modify or alter the construction of the fireplace or its components. Any modification
or alteration of construction may void the warranty, listings and approvals of this system. Country Flame Technologies
assumes no responsibility for damages or resultant injuries caused by any modification or alteration to an Inglenook.
This unit is listed to the following standards: UL 127-1999, ULC S610-98
PLEASE RETAIN THIS MANUAL
FOR FUTURE REFERENCE
COUNTRY FLAME TECHNOLOGIES
A Division of American Products, LLC
900 George Street
Marshfield, 65706
(417) 859-0990
WWW.COUNTRYFLAME.COM
TM
Vista de pagina 0
1 2 3 4 5 6 ... 53 54

Indice de contenidos

Pagina 1 - INGLENOOK™

INGLENOOK™ MODEL IWZC-02 ZERO CLEARANCE NON-CAT FIREPLACES OWNERS MANUAL © 2006 Version: 7.0 1This manual was written to ensure safe, efficie

Pagina 2 - TABLE OF CONTENTS

INGLENOOK FIREPLACE OPERATION FUEL The Inglenook should be fueled with seasoned cordwood. Hardwoods will provide more energy per pound of wood cons

Pagina 3

COMBUSTION CONTROL The Inglenook is not designed to operate with a flue damper. As is standard practice with hi-tech high efficiency fireplaces, the

Pagina 4 - Version: 7.0

FIGURE 2: HIGH BURN COMBUSTION AIR DAMPER SETTING CAUTION must be used when operating the Inglenook Fire

Pagina 5

change in the flame pattern. The flames will be slow and intermittent and may appear dirty if the wood is too wet i.e., a moisture content of 20% and

Pagina 6 - FOREWARD

2. Negative Pressure As the Inglenook fire burns, the exhaust gases are drafted up and out of the chimney system. The Inglenook Fireplace system is

Pagina 7 - SAFETY RULES

FIGURE 5: CHIMNEY INSTALLATION DIMENSIONS 7. Poor Chimney Draft Perform the following simple test of your chimney draft. With no fire

Pagina 8 - WARNOCK HERSEY SAFETY LABEL

MAINTAINING YOUR INGLENOOK FIREPLACE CREOSOTE When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moist

Pagina 9 - THE INGLENOOK FIREPLACE

4. Always use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use water as it may cause a dangerous steam explosi

Pagina 10 -

DOOR(S) INSTALLATION The Inglenook doors have been mounted and checked for proper fit at the factory. If the doors are removed for any reason, care

Pagina 11 - COMBUSTION CONTROL

hazardous to use. Inglenook Fireplace replacement glass can be purchased through one of Country Flame’s authorized dealers. DO NOT OPERATE the Ingle

Pagina 12 - Version: 7.0

TABLE OF CONTENTS COUNTRY FLAME LIMITED WARRANTY... 4 FOREWARD

Pagina 13

DOOR GASKET REPLACEMENT Remove the doors from the unit. Place the doors, face down on a protective surface to ensure no marring or scratching occurs

Pagina 14

FIREPLACE INSTALLATION INGLENOOK FIREPLACE LOCATION 1. The best location for your fireplace is determined by considering the location of windows, d

Pagina 15 - IMPORTANT NOTES

HEARTH EXTENSION REQUIREMENTS The Inglenook Fireplace can be installed directly on a combustible or non-combustible base or directly on the floor. I

Pagina 16

3. Frame the Inglenook Fireplace with vertical studs on each side of the fireplace. These studs should run from floor to ceiling as shown in Figure

Pagina 17

INSULATED CHASE CONSTRUCTION FIGURE 13: INSULATED CHASE FACING 1. Combustible material must be installed flush with the fireplace. It may not

Pagina 18

FIGURE 14: COMUSTIBLE FACING FIGURE 15: NON-COMBUSTIBLE FACING MANTEL CLEARANCES: Option 1: When in

Pagina 19

HOT AIR DUCT INSTALLATION There are many different types of hot air ducting systems in the marketplace today. Only a hot air duct system that has be

Pagina 20

FIGURE 18: HOT AIR DUCT KIT MULITPLE LOCATION INSTALLATION ot air duct outlets must be installed with the fo

Pagina 21 - FIREPLACE INSTALLATION

Inglenook Fireplace has not been tested for a Central forced air kit and should not be used in such applications. 7. Use only Country Flame approved

Pagina 22

OUTSIDE AIR KIT INSTALLATION A minimum of a four (4) inch hole is to be made in the outside wall of the house at the specified location for the fresh

Pagina 23

OUTSIDE AIR KIT INSTALLATION ... 29 ELECTRICAL LINE IN

Pagina 24 - INSULATED CHASE CONSTRUCTION

ELECTRICAL LINE INSTALLATION 120 VOLTS AC FOR BLOWER SYSTEM The Inglenook blower system requires a 120-volt alternating current, 15-ampere, 60-Her

Pagina 25

BLOWER OPERATION Operation of the blower system is relatively simple. After the fire has generated enough heat, the blower system will automat

Pagina 26 - HOT AIR DUCT INSTALLATION

THE CHIMNEY CHIMNEY INSTALLATION 1. If possible, always install an approved chimney system in an interior chase of the home. This will provide bet

Pagina 27

4. MINIMUM CHIMNEY HEIGHT: The chimney must be a minimum of 8’above top of fireplace. The chimney must extend a minimum of three feet above the high

Pagina 28

REMINDER: The chimney must extend at least three feet above the highest point where it passes through the roof of a building. The chimney must be at

Pagina 29

FIGURE 24: EXAMPLE MULTIPLE CHIMNEY INSTALLATION (INTERIOR SPACE) Version: 7.0 35

Pagina 30

Class A AC CHIMNEY INSTALLATION (AIR COOLED CHIMNEY) Version: 7.0 36FIGURE 25: AC CHIMNEY

Pagina 31

FIGURE 26: EXAMPLE CHIMNEY INSTALLATION (exterior space) Version: 7.0 37

Pagina 32 - THE CHIMNEY

CHIMNEY CHASE AND MULTIPLE TERMINATIONS For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part o

Pagina 33

CHIMNNEY TYPE WARNING: Use only 8-inch type HT or Air Cooled Chimney Listed per UL 103 or ULC S269. APPROVED CHIMNEY PRODUCT TYPE HT EIGHT INCH AP

Pagina 34

COUNTRY FLAME LIMITED WARRANTY 900 George Street, Marshfield, MO. 65706 Country Flame Technologies warrants to you, the original consumer purcha

Pagina 35

INSTALLATION ITEMS (REQUIRED) Item Required Required/Installation Inglenook Fireplace 1 each Inglenooks hold down system (mobile home only

Pagina 36 - FIGURE 25: AC CHIMNEY

APPENDIX A INGLENOOK FIREPLACE SPECIFICATIONS Fireplace Weight (with doors, glass, grills, and firebrick) 650 pounds Fireplace Weight (w/o doors

Pagina 37

problems occur or your glass needs replacement, contact one of the many authorized Country Flame dealers for assistance in replacing the glass. DO NO

Pagina 38

APPENDIX B CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation Sidewall: 18 inches measured f

Pagina 39

APPENDIX C REPLACEMENT PARTS Part Number Description Number per Inglenook PP-1194 Ash Grate 1 IN-201 Log Retainer/Security Kit 1

Pagina 40

REPLACEMENT PART DRAWINGS _______________________________________________________________________ _______________________________________________

Pagina 41 - Glass-Ceramic, ROBAX®

________________________________________________________________________ _______________________________________________________________________

Pagina 42

________________________________________________________________________ Version: 7.0 47

Pagina 43 - APPENDIX B

________________________________________________________________________ ____________________________________________________________________

Pagina 44 - APPENDIX C

________________________________________________________________________ ________________________________________________________________________

Pagina 46

________________________________________________________________________ Version: 7.0 50

Pagina 47

APPENDIX D WARNING LABELS Below is a sample list of the warning labels attached to the Country Flame Inglenook Fireplace product. It is important t

Pagina 48

WARNING LABEL: Electrical Hazard WARNING LABEL: FIRE HAZARD IF INTERFERENCE WITH AIRFLOW WARNING LABEL: INCLUDED ON BLOWER FAN LABEL:

Pagina 49

Fold Here - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Pagina 50

REQUIRED WARRANTY INFORMATION Name ________________________________________________ Address

Pagina 51 - APPENDIX D

FOREWARD Country Flame Technologies, A Division of American Products, LLC. and its employees would like to thank you for the purchase of an Inglenook

Pagina 52

Version: 7.0 7SAFETY RULES Warning: An outside air kit must be installed on the Inglenook Fireplace. Inglenook air openings are never to

Pagina 53 - Country Flame Technologies

8 WARNOCK HERSEY SAFETY LABEL Version: 7.0